In shortA certificate proves the heat was tested, not that the material in your yard is good. EN 10204 3.1 is issued by the manufacturer's inspection department against the ordered specification, and it says nothing about what happened after the bundle left the works. These notes cover what inspection catches, what it misses, and how to write a packing clause that prevents most of the damage.
Two failures account for most of the disputes we see, and neither is a metallurgy problem. The first is a certificate that was read as a warranty. The second is material that left the mill in specification and arrived out of it, because the packing was specified by habit rather than by the route it had to survive.
The pieces here are written from the receiving end. They assume the material is already on the water and ask what can still be proved, what has to be documented before it lands, and which clause would have prevented the argument. Where a claim is unwinnable, the page says so rather than describing a process we do not follow.
In this section
5 notes on quality and inspection
What an EN 10204 3.1 Certificate Does Not Cover
A 3.1 certificate records specific test results for one heat, validated by the mill's inspection representative. It does not prove that the piece in front of you came from that heat, that the finish is right, or that a 3.2 witness was involved.
2026-11-07 · Read →
What Third-Party Inspection Covers, and What It Misses
A clean eighteen-page report, and the plate arrives under-thickness. Nothing was falsified. The scope asked a different question.
2026-10-31 · Read →
Opening the Container: Handling a Stainless Surface Claim
A surface claim is usually lost as soon as the container opens. Photograph the seal and the first bundle in place, separate condensation from contamination and pitting, and send the heat number with the evidence.
2026-11-07 · Read →
What to Put in an Export Packing Specification
Ask three suppliers what seaworthy packing means and you get three answers. None of them is a specification you can inspect.
2026-10-31 · Read →
Filler Selection and Post-Weld Cleanup on Stainless Steel
Weld problems on stainless are usually decided away from the arc: the filler, the gas shield on the back of the root, and whether heat tint was removed. Match the filler to the base metal, then specify the cleanup.
2026-11-07 · Read →
Where to go next
Reference material behind these notes
Other sections
Grade comparisons
Head-to-head notes on the pairs that get quoted side by side, written from the service condition back to the alloy.
Grades and reference tables
Grade quick reference, the standard behind each form, and the weight basis on the invoice.
Standards and finishes
Which standard governs which form, what a finish designation commits to, and where the two systems disagree.
Trade and sourcing
RFQ wording, Incoterms, and the costs that appear between FOB and the yard.
Send the list, not the easy part